2.10 SPI Module API Manual#

1. Overview#

The K230 integrates three SPI hardware modules internally, supporting chip select polarity configuration and adjustable clock rates. The I/O configuration for channel output can refer to the IOMUX module.

2. API Introduction#

The SPI class is located in the machine module.

2.1 Example Code#

from machine import SPI

# Initialize SPI with a clock rate of 5 MHz, polarity 0, phase 0, and data width of 8 bits
spi = SPI(id, baudrate=5000000, polarity=0, phase=0, bits=8)

# Send data to the slave device
spi.write(buf)

# Read data into a variable while sending data
spi.write_readinto(write_buf, read_buf)

# Close the SPI
spi.deinit()

2.2 Constructor#

spi = machine.SPI(id, baudrate=20, polarity=0, phase=0, bits=8)

Parameters

  • id: SPI module ID, range [0~2] (corresponding to spi.SPI0 to spi.SPI2).

  • baudrate: SPI clock rate, calculated as ( F_{sclk_out} = \frac{F_{ssi_clk}}{BAUDR} ).

  • polarity: Clock polarity.

  • phase: Clock phase.

  • bits: Data width.

2.3 read Method#

spi.read(nbytes)

Reads the specified number of bytes.

Parameters

  • nbytes: Number of bytes to read.

Return Value

Returns a bytes object.

2.4 readinto Method#

spi.readinto(buf)

Reads data into the specified buffer.

Parameters

  • buf: A buffer of type bytearray.

Return Value

None

2.5 write Method#

spi.write(buf)

Sends data.

Parameters

  • buf: Data of type bytearray, defining the data to be sent and its length.

Return Value

None

2.6 write_readinto Method#

spi.write_readinto(write_buf, read_buf)

Reads data into the specified variable while sending data.

Parameters

  • write_buf: Data of type bytearray, defining the data to be sent and its length.

  • read_buf: A buffer of type bytearray to store the received data.

Return Value

None

2.7 deinit Method#

spi.deinit()

Unregisters the SPI module.

Parameters

None

Return Value

None